Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Eng Phys ; 126: 104155, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621851

RESUMO

The population of older adults is rapidly growing. In-home monitoring systems have been used to support aging-in-place. Ambient sensors or wearable localizers can be used but may be too low resolution, while camera systems are invasive to privacy. Ultra-wideband (UWB) localization offers precise positioning by placing anchors throughout the house and wearing a tag that is tracked by the anchors. In this study, the accuracy of UWB for indoor tracking was evaluated in a motion capture gait lab and in a mock condo in the Glenrose Rehabilitation Hospital. First, the configuration of UWB was tested, changing factors related to sampling time, anchor placement and line-of-sight. Comparing these factors to the configurations recommended by the manufacturer guidelines, accuracies remained within 14 cm. We then performed static and dynamic accuracy tests, with dynamic testing comprised of rolling and walking motions. In the motion capture lab, we found localization accuracies of 7.0 ± 11.1 cm while in the mock condo, we found accuracies of 27.3 ± 12.9 cm. Dynamic testing with rolling motions had an average of 19.1 ± 1.6 cm while walking was 20.5 ± 4.2 cm. The mean accuracy of UWB is within the 30 cm target for indoor localization.


Assuntos
Marcha , Caminhada , Movimento (Física) , Monitorização Fisiológica
2.
JMIR Rehabil Assist Technol ; 9(4): e42385, 2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36355405

RESUMO

BACKGROUND: Upper extremity function plays a critical role in completing activities of daily living, employment, and participating in recreational activities. The FEPSim device is a medical device for hand and wrist rehabilitation that can be adjusted according to the patient's requirements in rehabilitation. Furthermore, the FEPSim can be used to assess the patient's strength and range of motion of the forearm, wrist, and hand. At present, the acceptance and usability of the FEPSim have not been tested in a clinical setting, with limited perspectives from rehabilitation-providing clinicians. OBJECTIVE: This study aims to understand the factors related to the acceptance and usability of the FEPSim device. Upper limb disorders are prevalent across populations. The impact of upper limb disorders, both acute and chronic, puts a significant burden on the Canadian health care system. METHODS: A qualitative descriptive study was conducted that involved face-to-face semistructured interviews with hand therapists from hand therapy services who used the FEPSim device. We used purposive sampling to recruit 10 participants over a period of 14 months. Semistructured interview questions (topic-guided) examined the technology acceptance and usability of the FEPSim device. RESULTS: We found 6 factors to be critical aspects of the acceptance and usability of the FEPSim device. These factors were (1) useful for therapy, (2) effortlessness, (3) environmental conditions, (4) internal encouragement, (5) technological aesthetics, and (6) use. CONCLUSIONS: The FEPSim device was widely accepted by the therapists. The use of the FEPSim device is a feasible alternative for supporting hand therapy. TRIAL REGISTRATION: ISRCTN Registry ISRCTN13656014; https://www.isrctn.com/ISRCTN13656014.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...